4 - INSTALLATION NOTES
A minimum of two (2) WARNING SIGNS shall be installed, one on each side
of the gate where easily visible.
Test all features for proper functions before placing the automatic vehicular
gate opener into service.
Demonstrate the basic functions and safety features of the gate system to
owners/end users/general contractors, including how to turn off power and
how to operate the manual release feature.
Leave safety instructions, product literature, installation manual and
maintenance instructions with end user.
Explain to the owners/users the importance of a service contract that
includes a routine testing of the entire system including the entrapment
protection devices, and explain the need for the owners to insure that this
testing is performed routinely.
Offer the owner/end user a maintenance contract, or contact them regularly
to offer maintenance.
See instructions on the placement of non-contact sensors for each type of
application.
4.1 - Follow Instructions
Always follow all instructions included in this manual to ensure safety and the
longevity of the operator.
4.2 - Intended usage
THIS CIRCUIT BOARD IS INTENDED FOR USE WITH VEHICULAR SWING
AND SLIDE GATES ONLY.
4.3 - Warnings, cautions and notes
4.3.1 Gate terms “system, “gate operator”, “gate system”, and “gate
operator system” for these warnings, cautions, and notes is intended
to cover the gate controller, gate controller software, the gate actuator,
and all safety accessories included within a typical installation.
4.3.2 Gate system designers, installers and users must take into
consideration the inherent hazards associated with each installation,
since no two installations will be exactly alike.
4.3.3 Improperly designed, constructed, installed or maintained systems
can and may introduce hazards which may or may not be readily seen
or identied by users, bystanders, installers or inspectors
4.3.3 Improperly designed, constructed, installed or maintained systems
can and may introduce hazards which may or may not be readily seen
or identied by users, bystanders, installers or inspectors
4.3.4 All pinch points must be guarded or eliminated.
4.3.5 Only install this gate system opener in appropriate manners in which
the operation is safe and secure.
4.3.6 A gate operator exerts a great amount of force in order to move
the gate system in normal operation, therefore appropriate safety
sensors, measures, notices and appropriate safety features must be
incorporated in all installations.
4.3.7 The gate must be installed correctly and no binding or resistance
should be present throughout its movement in either direction.
4.3.8 The gate system must be installed in an area and in such a manner
in which the gate has sufcient clearance to open, close and
move without striking or contacting any structures and/or other
obstructions.
4.3.9 The gate system is designed for vehicular trafc only, and should
never, under any situation be used for pedestrian trafc
4.3.10 Pedestrian prohibited signs, warning signs or other suitable measures
must be used at minimum, to warn pedestrians to stay away from,
and to not use this system under any circumstances.
4.3.11 Pedestrians should be encouraged to use a pedestrian entry/exit only.
4.3.12 Pedestrians should never cross the path of a moving gate. The
sensors are designed to prevent contact with a vehicle and are
not necessarily capable of preventing contact with a pedestrian.
Care should be taken to prevent pedestrian usage under any
circumstances.
4.3.13 One or more non-contact sensors must be used in any situation or
area where entrapment may have the possibility of occurring.
4.3.14 Gates shall be constructed in accordance with the provisions given for
the appropriate gate type listed, refer to ASTM F2200 for additional
gate types.
4.3.15 Any existing manual gate latches shall be removed or disabled when
an automatic gate system is installed. Use only mag locks controlled
by the system
3.3 - Gate system safety devices
Automatic gate operators are designed to move a heavy steel gate. Great
amounts of force are sometimes used to move these heavy systems. The
automatic gate system may cause signicant damage or injury if the path of
the gate is obstructed. All sensors, safety devices and warning notices must
be in place and operable in order for this system to operate properly. It is the
installer’s responsibility to install this system properly and to ensure its correct
and safe operation.
3.4 - Infrared beams and warning signs
Infrared beams are used to inform the control board that an obstruction is
present. Safety devices must be installed properly and inspected periodically
to ensure continued reliability and safety. Safety devices, safety sensors,
warning signs and notices of moving equipment danger must be installed
and readily visible by all paths of approach to the gate system. Failure to post
warnings could result in loss of life, damage or physical injury.
3.5 - Establish the location
The installer of this system needs to establish the location of the opener in
accordance with instructions contained within this manual. A typical layout
is provided at the end of this manual with a nominal basic drawing. It is the
installer’s responsibility to ensure that the opener is installed in such a fashion
so as to prevent binding, pinching or improper articulation of the system
throughout its actuation cycle.
3.6 - Read and follow all instructions
3.7 - Keep children away
Never let children operate or play with gate controls. Keep the remote control
away from children.
3.8 - Test the gate system
The gate must reverse on contact with a rigid object or stop when an object
activates the non-contact sensors. After adjusting the force or the limit of
travel, retest the gate operator. Failure to adjust and retest the gate operator
properly can increase the risk of injury or death. Test force and correct
functionality for photo-eyes and other safety devices at least every 6 months.
ONLY USE the MANUAL RELEASE when the gate is not moving or when the
unit fails or in case of power outage.
• Turn the power to the gate controller OFF AND REMOVE BATTERIES
before using the emergency release.
3.9 - Keep gates properly maintained
Have only a qualied service person make repairs. Unqualied service
technicians are not recommended.
Before installing and/or operating the gate opener, installers and/or users
should do the following:
Conrm the gate operator being installed is appropriate for the application.
Conrm the gate is designed and built according to current applicable
published industry standards.
Conrm all appropriate features and accessory devices are being
incorporated, including both primary and secondary entrapment protection
devices.
Make sure the gate works freely before installing the operator.
Repair or service worn or damaged gate hardware before installing the
operator.
Adjust the FORCE device to the minimum force setting that allows reliable
gate operation.
Install operator inside fence line (DO NOT install operator on public side of
fence line).
Swinging gates shall not open into public access areas.
Install a proper electrical ground to a gate operator.
Install keypad controls where users cannot touch, or reach through gate
while operating controls, which is a minimum of 8 feet from the gate.
Install controls where user has full view of gate operation.
Install all warning signs on both sides of the gate to warn persons in
the area of potential hazards associated with automatic vehicular gate
operation.